Global Global Algérie Français Algeria English Angola Português Angola English Argentina Español Argentina English Australia English Austria Deutsch Austria English Azerbaijan English Azerbaijan Русский Bahrain English Bangladesh English Belgium English Belgium Français Belgium Nederlands Brazil Português Brazil English Bulgaria български Bulgaria English Cameroon English Cameroon Français Canada English Canada Français Chile Español Chile English China 中文 China 日本語 China English Colombia Español Colombia English Croatia English Czech Republic Čeština Czech Republic English Denmark English Djibouti English Ecuador Español Ecuador English Egypt English Estonia English Ethiopia English Finland Suomi Finland English France Français France English Georgia English Georgia Русский Germany Deutsch Germany English Ghana English Greece Ελληνικά Greece English Guatemala Español Guatemala English Hong Kong, China English Hong Kong, China 中文 Hungary Magyar Hungary English India English Indonesia English Iraq English Ireland English Italy Italiano Italy English Ivory Coast Français Ivory Coast English Japan 日本語 Japan English Jordan English Kazakhstan Русский Kazakhstan English Kenya English Kuwait English Kyrgyzstan Русский Kyrgyzstan English Latvia English Lithuania English Malaysia English Mauritius English Mauritius français (Maurice) Mexico Español Mexico English Moldova Română Moldova English Mongolia English Morocco English Morocco Français Mozambique Português Mozambique English Netherlands Nederlands Netherlands English New Zealand English Nigeria English Norway English Oman English Pakistan English Paraguay Español Paraguay English Peru Español Peru English Philippines English Poland Polski Poland English Portugal Português Portugal English Qatar English Republic of Korea 한국어 Republic of Korea English Romania Română Romania English Saudi Arabia English Serbia Српски Serbia English Singapore English Slovakia English Slovenia English South Africa English Spain English Spain Español Sri Lanka English Sweden English Switzerland Deutsch Switzerland Français Switzerland Italiano Switzerland English Tanzania English Thailand ไทย Thailand English Togo English Togo Français Tunisia English Tunisia Français Türkiye Türkçe Türkiye English Turkmenistan Русский Turkmenistan English Ukraine Українська Ukraine English United Arab Emirates English United Kingdom English Uruguay Español Uruguay English USA English Uzbekistan English Uzbekistan Русский Vietnam Tiếng Việt Vietnam English

Plastic Flame Retardant Rating Assessment: Standards, Test Methods and Classification Guide

Plastic flame retardant rating assessment measures how polymeric materials ignite, burn, drip, and self-extinguish under standardized flame exposure, forming the foundation of fire-safety compliance for electrical, electronic, automotive, and construction products. This technical guide explains the major flammability classification systems, sample requirements, test procedures, and acceptance criteria defined by UL, IEC, ISO, ASTM, and GB standards, helping manufacturers select the appropriate test program at accredited third-party laboratories.

Technical Overview

Plastic flame retardant rating assessment is a laboratory evaluation of the flammability characteristics of polymeric materials, including ease of ignition, burning rate, ability to self-extinguish after removal of the ignition source, afterflame and afterglow duration, and the tendency to produce flaming droplets or particles. Because most plastics are organic compounds composed of carbon and hydrogen, they are inherently combustible, and their fire behavior must be quantified before they can be used in safety-critical applications.

The most widely applied classification framework is the UL 94 series, which is technically aligned with IEC 60695-11-10, IEC 60695-11-20, ISO 1210, ISO 9772, and ISO 9773, as well as the corresponding Chinese national standards GB/T 2408, GB/T 5169.16, GB/T 5169.14, and GB/T 5169.13. Complementary methods such as the glow wire tests of IEC 60695-2-10 to IEC 60695-2-13 and the limiting oxygen index (LOI) tests of ISO 4589 and ASTM D2863 provide additional data on ignition resistance and intrinsic combustibility. The resulting ratings are cited in material datasheets, end-product safety standards, and regulatory submissions, and they directly influence material selection for enclosures, connectors, structural parts, and internal components.

Testing Samples

Standard Bars and Plaques

For horizontal and vertical burning tests, specimens are typically cut or molded to 125 mm × 13 mm rectangular bars at the minimum and intermediate wall thicknesses of the intended application, commonly 1.5 mm and 3.0 mm. Testing multiple thicknesses is essential because flammability performance degrades as thickness decreases, and a rating is only valid at or above the thickness actually tested.

Thin Films and Flexible Materials

Materials thinner than about 0.25 mm that distort or shrink when clamped cannot be evaluated with the standard vertical method. They are assessed using the VTM (vertical thin material) configuration, in which the specimen is wrapped around a mandrel and mounted with its axis horizontal before flame exposure.

Cellular and Foam Materials

Rigid and flexible foams are evaluated under dedicated horizontal and vertical procedures described in ISO 9772, which account for the distinct burning and melt behavior of low-density cellular structures. Ratings are reported as HF-1, HF-2, or HBF classifications.

Finished Products and Components

In addition to raw material plaques, completed parts such as housings, terminal blocks, coil bobbins, and decorative trims can be assessed directly. End-product testing reflects the influence of geometry, wall thickness variation, proximity of ignition sources, and the presence of adjacent combustible or metallic parts.

Testing Items

A comprehensive flame retardant evaluation typically covers the following items, selected according to the product standard and the intended application:

  • UL 94 HB horizontal burning classification for the least stringent applications
  • UL 94 V-0, V-1, and V-2 vertical burning classifications at 50 W flame power
  • UL 94 5VA and 5VB vertical burning classifications at 500 W flame power
  • UL 94 VTM-0, VTM-1, and VTM-2 classifications for thin flexible materials
  • HF-1, HF-2, and HBF classifications for cellular polymeric materials
  • Glow wire flammability index (GWFI) per IEC 60695-2-12
  • Glow wire ignition temperature (GWIT) per IEC 60695-2-13
  • Limiting oxygen index (LOI) per ISO 4589-2 and ASTM D2863
  • Needle flame test per IEC 60695-11-5 for small components

Testing Methods

Horizontal Burning Test (HB)

A test bar is clamped horizontally, and a 20 mm methane flame is applied to the free end for 30 seconds. The material is classified HB if the burning rate does not exceed 40 mm/min for bars 3 mm to 13 mm thick, does not exceed 75 mm/min for bars less than 3 mm thick, or if burning stops before the 100 mm reference mark. Many end-product standards permit HB materials only in non-critical, low-risk locations.

Vertical Burning Test at 50 W (V-0, V-1, V-2)

The specimen is clamped vertically with a cylinder of surgical cotton placed 300 mm below its lower edge. A 20 mm flame is applied to the bottom of the bar for 10 seconds, removed, and then reapplied for a second 10 seconds after the specimen stops burning. Classification depends on the afterflame time after each application, the total afterflame plus afterglow time for the specimen pair, whether the clamp is reached, and whether flaming drips ignite the cotton. For V-0, each afterflame time must be within 10 seconds and the total within 50 seconds with no flaming drips; V-1 allows 30 seconds and 250 seconds with no flaming drips; V-2 has the same timing limits as V-1 but permits flaming drips that ignite the cotton.

Vertical Burning Test at 500 W (5VA, 5VB)

A higher-energy 125 mm flame is applied five times for 5 seconds each to vertical bars and to horizontal plaques. 5VA, the highest UL 94 classification, requires that no flaming drips occur, the plaque is not burned through, and afterflame plus afterglow does not exceed 60 seconds after the fifth application. 5VB permits plaque burn-through holes but retains the prohibition on flaming drips. These ratings are commonly mandated for unattended appliances and fire enclosures.

Glow Wire Testing

A nickel-chromium glow wire heated to a controlled temperature between 550 °C and 960 °C is pressed against the specimen for 30 seconds. GWIT records the temperature 25 K above the highest temperature at which no ignition occurs in three consecutive trials, while GWFI records the highest temperature at which the specimen self-extinguishes within 30 seconds after glow wire removal without igniting the underlying tissue paper. These methods simulate thermal stress from overheated or glowing components and are required by IEC 60335, IEC 60950, and IEC 62368 product families.

Limiting Oxygen Index

The LOI test determines the minimum concentration of oxygen, expressed as a volume percentage in an oxygen-nitrogen mixture, that just supports candle-like combustion of a vertically mounted specimen for 3 minutes or over 50 mm of its length. Materials with LOI values above approximately 21, the oxygen content of air, are considered self-extinguishing in normal atmospheres, making LOI a useful comparative parameter for compound development and quality control.

Applications

Flame retardant rating assessment supports material qualification and regulatory compliance across a broad range of industries:

  • Consumer electronics and IT equipment enclosures, chargers, and battery housings
  • Electrical components such as connectors, switches, relays, sockets, terminal blocks, and circuit breakers
  • Home appliances, including unattended appliances subject to glow wire requirements
  • Automotive interior trim, connectors, and charging infrastructure components
  • Wire and cable insulation, sheathing, and accessories
  • Building and construction products, decorative materials, and rail or air transport interiors
  • Medical device housings and laboratory instrumentation

FAQ

What is the difference between V-0 and V-2?

Both ratings use the same 50 W vertical test and share the timing limits of a maximum 30-second afterflame per ignition and 250 seconds total. The key difference is dripping behavior: V-0 requires faster self-extinguishing (10 seconds per application, 50 seconds total) and no flaming drips, whereas V-2 permits flaming particles that ignite the indicator cotton. V-0 is therefore required for parts positioned above live circuits or near combustible materials.

How does specimen thickness affect the rating?

Flame ratings are thickness dependent. Thin sections ignite more easily and burn longer, so a material certified V-0 at 3.0 mm may only achieve V-1 or V-2 at 1.5 mm. The reported rating is valid only for wall thicknesses equal to or greater than the tested thickness, and end-product standards typically specify the minimum thickness required for each intended use.

Are UL 94 and IEC 60695-11-10 results interchangeable?

The two standards are technically harmonized and produce equivalent V-0, V-1, and V-2 classifications, with only minor differences in apparatus and reporting details. Many accredited third-party laboratories issue combined reports referencing both standards. However, product certification schemes may still specify the exact standard edition that must be cited.

Do colorants and additives influence test results?

Yes. Pigments, release agents, fillers, and reinforcing fibers can measurably alter ignition time, afterflame duration, and drip behavior. For this reason, certification testing should be performed on the actual compounded and colored grade that will be used in production, rather than on a natural, unpigmented version of the resin.

How many specimens are required and how should they be conditioned?

A typical vertical burning program uses two sets of five bars at each thickness, one set tested as received and one after conditioning. Specimens are conditioned at 23 ± 2 °C and 50 ± 5 % relative humidity for at least 48 hours in accordance with ISO 291 or ASTM D618, and some specifications additionally require testing after accelerated aging.

Can a raw material rating be transferred to the finished product?

A material-level UL 94 rating demonstrates the capability of the compound, but the final part must still satisfy the end-product standard, which considers part geometry, wall thickness, distance to ignition sources, and enclosure design. Where the product standard requires it, glow wire, needle flame, or component-level burning tests must be performed on the actual manufactured article.